Specification |
Value |
Magnification |
0.243 (x) |
Magnification ranges at -2 dpt to +3 dpt |
0.239 – 0.250 (x) |
Image circle diameter |
11.0 (mm) |
Max sensor size |
2/3″ |
1/3″ |
19.75 x 14.81 (mm x mm) |
1/2.5″ |
23.46 x 17.61 (mm x mm) |
1/2″ |
26.34 x 19.75 (mm x mm) |
1/1.8″ |
29.34 x 21.93 (mm x mm) |
2/3″ |
34.98 x 29.18 (mm x mm) |
Working distance |
101.5 (mm) |
Working distance range |
122.9 – 73.2 (mm) |
Working distance repeatability |
±0.5 (small steps); ±1 (large steps) (mm) |
Working f/N |
8 |
Telecentricity typical (max) |
< 0.08 (0.1) (deg) |
Telecentricity max |
< 0.15 (deg) |
Distortion typical (max) |
< 0.04 (0.1) (%) |
Distortion max |
< 0.15 (%) |
Depth of field |
7.00 (mm) |
Resolution |
21 (μm) |
Liquid lens model |
Optotune EL-16-40 |
Temperature sensor |
Yes |
Focal power mode |
Yes |
Response time |
5 (ms) |
Setting time |
25 (ms) |
Current range |
-500 to +500 (mA) |
Repeatability using focal power mode |
±0.05 (small steps); ±0.1 (large steps) (dpt) |
Lifecycles (10%-90% sinusoidal) |
>1,000,000,000 |
Connector |
HR10A-7R-6PB |
Mount |
C |
Phase adjustment |
Yes |
Length |
166.4 (mm) |
Front diameter |
61.0 (mm) |
Mass |
539 (g) |
Operating temperature |
0-40 (°C) |
Storage temperature |
0-50 (°C) |
Operating relative humidity |
20-85, non condensing (%) |
Installation |
Indoor use only |